CHARGING ALGORITHM OF OPTIMATE III, SHOWING FIRST TWO FLOAT CHARGE PERIOD OF 30 MINUTES AND FIRST 30 MINUTE PAUSE TO CHECK FOR SELF-DISCHARGE TENDENCY.  AMPS : VOLTS

 

NOTES :

1)       IN RECOVERY STAGE, THE CIRCUIT OFFERS THE BATTERY A FIXED CURRENT OF 200mA AND CHECKS THE RESULTANT VOLTAGE. IF THE BATTERY IS DEEP-DISCHARGED (SULFATED), THE VOLTAGE EXCEEDS 13.9V. THE CIRCUIT RESETS THE VOLTAGE LIMIT AT +/- 20V, WHILE CONTINUING TO TRY TO DELIVER A FIXED 200mA. IF & WHEN THE BATTERY ACCEPTS THIS CURRENT THE VOLTAGE WILL GRADUALLY REDUCE AND WHEN IT REDUCES BELOW 13.9V THE VOLTAGE LIMIT IS RESET AT 14.3V FOR THE BULK CHARGE STAGE.  FOR A BATTERY WHICH IS NOT SULFATED THE CIRCUIT PROCEEDS IMMEDIATELY TO BULK CHARGE.

2)       IF THE RECOVERY ACTION WAS NOT SUCCESSFUL AFTER 2 HOURS, THE CIRCUIT GOES AUTOMATICALLY INTO THE BULK CHARGE STAGE. THE BULK CHARGE STAGE TERMINATES WHEN THE CONSTANT CURRENT CAUSES THE VOLTAGE TO RISE TO 14.3V.

3)       TO COMPLETE THE VERIFICATION STAGE, THE BATTERY MAY NOT DRAW MORE THAN 200mA WITHIN 30 MINUTES OF THE END OF THE BULK CHARGE STAGE, AND, THE ACTUAL VOLTAGE MAY NOT REDUCE BY MORE THAN  300mV BELOW THE 13.6V FLOAT VOLTAGE SETTING.

IF EITHER EVENT SHOULD OCCUR,  THE CIRCUIT REVERTS TO BULK CHARGE UNTIL THE LIMIT OF 14.3V IS REACHED AGAIN, WHEREUPON THE TIMER RESETS TO ZERO, AND ANOTHER TIMED FLOAT STAGE COMMENCES.

4)       WHEN 30 MINUTES HAVE PASSED WITHOUT A REVERSION TO THE BULK CHARGE STAGE, THE CIRCUIT PAUSES FOR 30 MINUTES TO CHECK FOR SELF-DISCHARGE. NO CURRENT IS OFFERED DURING THIS PERIOD. THE VOLTAGE IS MONITORED. IF THIS FALLS BELOW 12.3V THE RED “WEAK BATTERY” WARNING LED INDICATES. OTHERWISE, THE GREEN “GOOD BATTERY” LED INDICATES.

5)       THE CYCLE OF 30 MINUTES PAUSE FOR SELF-DISCHARGE CHECK AND THEN 30 MINUTES FLOAT CHARGE, CONTINUES UNTIL THE OPTIMATE IS DISCONNECTED.

 